Uni Fibre Uses
High Performance Polypropylene Fibres For Concrete & Mortar
Durability
To improve the durability of cementations screeds and toppings by inhibiting the formation of small cracks, which occur because of plastic shrinkage and settlement due to premature drying.
Increased Residual strength
Durability is further enhanced due to increased residual
strength, resulting in improved abrasion, impact and spalling
resistance.
Even distribution
Even distribution throughout the mix is due to Fibers being coated with a special dispersing agent. Improves Fiber bond and eliminates the requirement for shrinkage control wire mesh reinforcement.
Internal & External Plaster
Can be used for internal & external plaster, concrete
repairs, precast concrete railway sleepers etc.
Uni Fibre Advantages
- Inhibits plastic shrinkage and settlement cracking
- Eliminates shrinkage control wire reinforcement
- Cost effective compared with wire reinforcement
- Specially pre-bagged to ensure correct dosing
- Improved abrasion, frost and impact resistance (good drop hammer results)
- Over 300 million Fibers per m3 of screed
- Controlled dispersion throughout the mix
- Reduced permeability and water absorption
- Reduced segregation and bleeding
- Improves surface finishing
- Alkali resistant and will not corrode.
- Can be used with all types of cement.
- Used as a secondary reinforcement in concrete
- Improves tensile and compressive strength
Typical Properties & Specifications
Sr. No. | Properties | Specification |
---|---|---|
1 | Denier (As per DIN - 53812) | 6.30 |
2 | Tenacity (As per DIN - 53816) | 4.63 |
3 | Material | 100% Virgin polypropylene |
4 | Length | 6mm, 10 mm & 12 mm. |
5 | Diameter | 30 to 100 micron |
6 | Surface characteristics | Lustrous white rough surface. |
7 | Elongation | 55% |
8 | Modulus of Elasticity | 1240 - 1517 Mpa |
Melting Point | 160ºC- 170ºC | |
9 | Ignition Point | 590ºC |
10 | Thermal Conductivity | Low |
11 | Electrical conductivity | Low |
12 | Acid & Salt Resistance | High |
13 | Absorption | Nil |
Instruction for Uni Fibre Use
High Performance Polypropylene Fibres For Concrete & Mortar
Mixing
Placing
Finishing
Curing
Packing & Dosage
Dosage : 125 gms. / 50 kg. bag of cement
Shelf Life & Storage
Quality Assurance
The company's quality system conforms to ISO 9001:2015.
Health & Safety
Uni Fibre Limitations
Uni Fibre Cannot be used as a replacement for structural steel reinforcement.
Uni Fibre Consumption
Approx. 1 kg of 12 mm Uni Fibre PP per cubic meter of screed or topping.