Uni Plast W is supplied as a yellowish liquid. When added to cementitious mixes it accelerates hydration and enables the water content to perform more efficiently by dispersing agglomerated cement particles. This further improves strength by enabling water reduction to be made at constant workability. Where there is embedded or prestressed steel, or where sulphate resistant cement is used or when steam curing is employed, Uni Plast W ideal for providing increased resistance to frost damage during and after construction of hollow blocks. Ideal for block making. Use of Uni Plast W reduces the damage in transportation of Blocks. Uni Plast W is an accelerating admixture that enhances the early strength of concrete..
Uni Plast W Uses
Accelerating Admixture For Unreinforced Cement Concrete/mortar
Uni Plast W is an effective and economical accelerating admixture for use in cold weather concreting applications. Cold temperature may slow down the hydration process and may damage the hardened concrete properties if not treated properly. The slower hydration process can be overcome by the use of this accelerating admixture. Because Uni Plast W contains Calcium Chloride, it is not recommended for use in prestressed concrete, post-tensioned concrete, nor reinforced concrete structures. Concrete can be done in cold weather, Mass concreting under sea water and concrete hollow block manufacturing. Can be used for P.C.C. work, hollow blocks and concrete bricks.

Uni Plast W Advantages
- Increase early strength gain allows earlier structural use and speeds completion time
- Saves time and money by allowing faster finishing and stripping of concrete form work
- Accelerates the hardening of floors and screeds
- Resistant to freezing in cold weather concreting
- Insulation and heating costs during curing time are reduced.
- Earlier stripping and reuse of forms increases labor productivity
- Accelerated strength gain
Typical Properties & Specifications
Sr. No. | Properties | Specification | ||
---|---|---|---|---|
1 | Specific Gravity | 1.290 + 0.020 | ||
2 | Physical Appearance | Yellowish liquid | ||
3 | Air entrainment | Less than 1% | ||
4 | Compatibility | Compatible with ordinary and rapid hardening Portland cement but not high alumina or sulphate resisting cements | ||
5 | Setting times | Typical results using UNIPLAST W 0 are given below at 30 C | ||
Trial Mix | W/C Ratio | IST | FST | |
Control | 0.55 | 4 hours | 6 hours | |
SAYOPLAST W | 0.55 | 1 hRrs. 45 Mins. | 3 hrs. 30 mins. |
Instruction for Uni Plast W Use
Accelerating Admixture For Unreinforced Cement Concrete/mortar
Add the correct amount of Uni Plast W at the concrete plant. The admixture may be added manually or by automated dispenser directly into the mixture or into the water at the batch plant.